EVCE-SV08-33
Configure EVOTEK products according to your requirements. Go to options to see all configuration possibilities.
Description
Technical Specifications
Operating Pressure :207Bar
Flow:11.4L/min
Internal leakage:82ml/min at 207bar
Operating temperature:-30°C to+ 120°C(-22°F to+ 250°F)
Cavity :VC08-3
Fluids:Mineral based or synthetic hydraulic fluid with lubricating properties
Fluid viscosity range :7.4 to 420cSt.
Features
Hardened seat for long life
Compact size
Industry common cavity
Continuous-duty rated solenoid
Optional coil voltages and terminations
Operation
When energized, the EVCE-SV08-33 allows flow from port 1 to port2, while blocking flow at
port 3. When de-energized, the cartridge’s spool shifts to open from port 3 to port 1, while
blocking flow out port 2.